Features
. 2.8-inch TFT LCD screen (320×240) with rich display contents
. The operation process is simple and convenient,
and with visual interface display system, it is easy to get started
. Key lock function to prevent misoperation
. Provides CC, CV, CR, CP and CC+CV, CR+CV several basic measurement modes
. Provides professional battery test and LED test
. The Tran test mode can test the dynamic output performance of the power supply
. The scan test mode can test the continuity of power output within a certain range
. The list test mode can simulate a variety of loading status changes
. The short circuit test can be used to simulate load short circuit
. Built-in buzzer alarm
. Maintain data storage in case of power failure
. Remote operation via USB, software optional
. Provides over current, over voltage, over power, over temperature protection.
The over voltage and over current parameters can be set flexibly
. It has intelligent fan speed control function, which can effectively reduce the fan noise
. With input polarity reverse protection
Technical Data | ELD5410 | ELD5420 | ELD5411 | |
Channels | Single Channel | Double channels | Single Channel | |
Rated input | Power | 400W | 400W (200W × 2) | 400W |
Input voltage | 0-150V | 0-150V | 0-500V | |
Input current | 0-40A | 0-20A × 2 | 0-15A | |
CV mode | Range | 0.1~19.999V,0.1~150.00V | 0.1~19.999V, 0.1~500.00V | |
Resolution | 1mV,10mV | |||
Accuracy | ±(0.05%+0.02%FS) | |||
CC mode | Range | 0~3.000A,0~40.00A | 0~3.000A,0~20.00A | 0~3.000A,0~15.00A |
Resolution | 1mA,10mA | |||
Accuracy | ±(0.05%+0.05%FS) | |||
CR mode | Range | 0.05Ω~1 kΩ,1 kΩ~4.5kΩ | ||
Resolution | 10mΩ,100mΩ | |||
Accuracy | ±(0.1%+0.5%FS) | |||
CP mode | Range | 0~400W | 0~200W | 0~400W |
Resolution | 10mW | |||
Accuracy | ±(0.1%+0.5%FS) | |||
Tran Test | Mode | CC,CV | ||
T1 & T2 | 1ms~60s (1ms resolution) | |||
Accuracy | 0.1%+1ms | |||
Battery Test | Discharge mode | CC,CR | ||
Maximum discharge capacity | 9999Ah | |||
Resolution | 1mA,10mA,10mΩ,100mΩ | |||
Voltage Measuring | Range | 0~19.999V,0 ~150.00V | 0~19.999V,0~500.00V | |
Resolution | 1mV,10mV | |||
Accuracy | ±(0.05%+0.1%FS) | |||
Current Measuring | Range | 0~3.000A,0~40.00A | 0~3.000A,0~20.00A | 0~3.000A,0~15.00A |
Resolution | 1mA,10mA | |||
Accuracy | ±(0.05%+0.1%FS) | |||
Power Measuring | Range | 0~400W | 0~200W | 0~400W |
Resolution | 10mW | |||
Accuracy | ±(0.1%+0.5%FS) | |||
Short Circuit | Current (CC) | ≈3A, ≈40A | ≈3A, ≈20A | ≈3A, ≈15A |
Voltage (CV) | 0V | |||
Resistance (CR) | ≈40mΩ | |||
Over Voltage Protection (OV) | >155V cut off input | >510V cut off input | ||
Over Current Protection (OC) | >42A cut off input | >22A cut off input | >16A cut off input | |
Over Power Protection (OP) | 420W | 220W | 420W | |
Over Temperature Protection | 85℃ | |||
Power Source | 100VAC±10%~240VAC±10%, 50/60Hz | |||
Dimension (W x H x D) | 90mm × 190mm × 300mm | |||
Weight | 3 KG |