DQ3025CL
HAND HOLD DIGITAL STORAGE OSCILLSCOPE
Features
.Digital oscilloscope and multimeter, 2 in 1
.Compact design for easy carrying
.High performance battery for long time operate
.3.5 inch TFT display with high resolution
| Technical Data | DQ3025CL | DQ3050CL | DQ3025DL | DQ3050DL | |
| Bandwidth | 25MHz | 50MHz | 25MHz | 50MHz | |
| Channel(s) | 1 | 1 | 2 | 2 | |
| Acquisition mode | Real time, peak detect, averaging | ||||
| Sample | Real time | 200M Sa/s | 200M Sa/s | 250M Sa/s | 250M Sa/s |
| Display | Type | 3.5″TFT display | |||
| Resolution | 320×240 | ||||
| Backlight intensity | 300 nit | ||||
| Backlight brightness | Adjustable | ||||
| Input | Input coupling | DC, AC, GND | |||
| Input impedance | 1MΩ±2%, 20pF±3pF | ||||
Probe attenuation | 1×, 10×, 100×, 1000× | ||||
| Max. input voltage | 300V (DC+AC peak) | ||||
Horizontal | Time base range | 10ns/div~ | 5ns/div~ | 10ns/div~ | 5ns/div~ |
| Time base accuracy | ±50ppm | ||||
Waveform | Sin(x)/x | ||||
| Recording length | 3.5M | ||||
| Storage depth | 12k | ||||
Delta time | single: ±(1 sampling interval time + 50ppm×rdg + 0.6ns) | ||||
Vertical | Resolution | 8 bits | |||
| Sensitivity | 5mV/div~20V/div | ||||
| Rise time | ≤14ns | ≤7ns | ≤14ns | ≤7ns | |
Low frequency | ≤10Hz (at the input BNC port) | ||||
| DC gain accuracy | ±4%(5mV/div), ±3%(10mV~20V/div) | ||||
Delta voltage | ±(3%Rdg+0.05div) | ||||
| Trigger | Trigger mode | Auto, normal, single | |||
| Type | Edge, pulse width, video, slope | ||||
| Hold off range | 100ns~1.5s | ||||
| Measurement | FFT | Hanning, Hamming, Biackman, Rectangular | |||
| Cursor | Voltage difference (ΔV) between cursors | ||||
| Auto-mesure | Vrms, Varg, Vp-p, Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, +Duty, -Duty, Delay | ||||
Digital characterizes | Resistance | 400Ω,4kΩ,40kΩ,400kΩ,4MΩ,40MΩ | |||
| Accuracy | ±(1.2%+5digits) | ||||
| DC voltage | 400mV, 4V, 40V, 400V | ||||
| Accuracy | ±(1%+5digits) | ||||
AC voltage | 400mV, 4V, 40V, 400V | ||||
| Accuracy | ±(1.2%+5digits) | ||||
| DC current | 400μA, 4000μA, 40mA, | 400μA, 4000μA, 40mA, | |||
| Accuracy | ±(1.2%+5digits)(μA) | ±(1.2%+5digits)(μA) | |||
AC current (45Hz~400Hz) | 400μA, 4000μA, 40mA, | 400μA, 4000μA, 40mA, | |||
| Accuracy | ±(2%+5digits)(μA) | ±(2%+5digits)(μA) | |||
| Capacitance | 51.2nF, 512nF, 5.12μF, 51.2μF, 100μF | ||||
| Accuracy | ±(3%+5digits) | ||||
| On/off | √ (≤75Ω) | ||||
| Diode | √ (0V~1.5V) | ||||
| Power source | AC: 100~240VACrms, 45~440Hz, CATⅡ | ||||
| Dimensions(W×H×D) | 199×118×49mm | ||||
| Weight | 0.9kg | ||||
| Accessories | Operation manual, adapter, probe×1 (CL series), probe×2 (DL series), multimeter pen×2, current-voltage convertor module×1, USB cable | ||||