PTL-936 SERIES PROBE Feature | ![]() |
| Specifications | PTL-936-60 | PTL-936-100 |
| Attenuator | X1/X10 | |
| System Rise-time(ns) | 23.3/3.5 | |
| System Bandwidth (3dB)MHz | X1: DC-6MHz | X1: DC-6MHz |
| X10: DC-60MHz | X10: DC-100MHz | |
| Voltage Max. | X1: 300V (DC + Peak AC) | |
| X10: 600V (DC + Peak AC) | ||
| Compensation range(pf) | 15~45 | 20~45 |
| Input Res.(Mohm) | 1/10 | |
| Input Cap.(Pf) | X1: 85pF~120pF | |
| X10: 18.5pF~22.5pF | ||
| Cable length | 120cm | 120cm |
| PTL938 SERIES PROBE .with color cable marker rings .Meet IEC-1010, 600Vpp, CATIII | ![]() |
| Specifications | PTL-938-20 | PTL-938-40 | PTL-938-60 | PTL-938-100 | PTL-938-200 |
| Attenuator | X1/X10 | ||||
| System Rise-time(ns) | ≤17.5ns | ≤8.75ns | ≤5.8ns | ≤3.5ns | ≤1.75ns |
| System Bandwidth (3dB)MHz | X1: DC-6MHz | X1: DC-6MHz | X1: DC-6MHz | X1: DC-6MHz | X1: DC-6MHz |
| X10: DC-20MHz | X10: DC-40MHz | X10: DC-60 | X10: DC-100MHz | X10: DC-200 | |
| Voltage Max. | X1: 300V (DC + Peak AC) | ||||
| X10: 600V (DC + Peak AC) | |||||
| Compensation range(pf) | 15~45/10~35 | ||||
| Input Res.(Mohm) | 1/10 | ||||
| Input Cap.(Pf) | X1: 85pF~120pF | ||||
| X10: 18.5pF~22.5pF | |||||
| Cable length | 120cm | 120cm | |||
| PTL-940SERIES PROBE .Bandwidth up to 100MHz .Meet IEC-1010, 2000Vpp, CATI | ![]() |
| Specifications | PTL-940-100 |
| Attenuator | X100 |
| System Rise-time (ns) | ≤3.5ns |
| System Bandwidth (3dB) MHz | 100MHz |
| Voltage Max. | 2000V (DC + Peak AC) |
| Compensation range (pf) | 10~35 |
| Input Res.(Mohm) | 100 |
| Input Cap.(Pf) | 5pF |
| Cable length | 120cm |
| PTL-970 SERIES PROBE Feature .Max. Test voltage up to 5kV | ![]() |
| Specifications | PTL971-30 | PTL971-50 | PTL975-30 | PTL975-50 |
| Attenuator | X10 | X10 | X100 | X100 |
| System Rise-time(ns) | ≤1.15ns | ≤0.7ns | ≤1.15ns | ≤0.7ns |
| System Bandwidth (3dB)MHz | 300MHz | 500MHz | 300MHz | 500MHz |
| Voltage Max. | 1kV (DC + Peak AC) | 1kV (DC + Peak AC) | 5kV (DC + Peak AC) | 5kV (DC + Peak AC) |
| Input Res.(Mohm) | 10 | 10 | 100 | 100 |
| Input Cap.(Pf) | 16 | 16 | 6.5 | 6.5 |
| Cable length | 130cm | |||
| PTL-960 SERIES PROBE .With a metal-box which has high frequency compensation hole for HF adjust on any oscilloscope .Meet IEC-1010, 600Vpp, CATIII | ![]() |
| Specifications | PTL-960-25 | PTL-960-30 | PTL-960-50 |
| Attenuator | X10 | ||
| System Rise-time(ns) | ≤1.4ns | ≤1.15ns | ≤0.7ns |
| System Bandwidth (3dB)MHz | X1: DC-6MHz | X1: DC-6MHz | X1: DC-6MHz |
| X10: DC-250MHz | X10: DC-300MHz | X10: DC-500MHz | |
| Voltage Max. | 600V (DC + Peak AC) | 600V (DC + Peak AC) | 600V (DC + Peak AC) |
| Compensation range(pf) | 9~30 | 9~25 | 9~25 |
| Input Res.(Mohm) | 10 | 10 | 10 |
| Input Cap.(Pf) | 12~15 | 10~13 | 10~13 |
| Cable length | 120cm | 120cm | 120cm |
| PTL-955 SERIES PROBE | ![]() |
| Specifications | PTL-955-I | PTL-955-II | PTL-955-III |
| Attenuator | X1000 | ||
| System Rise-time(ns) | ≤17.5ns | ||
| System Bandwidth (3dB)MHz | 20MHz | ||
| Voltage Max. | 10kV (DC + Peak AC) | 20kV (DC + Peak AC) | 40kV (DC + Peak AC) |
| Compensation range(pf) | 9~30 | 9~25 | 9~25 |
| Input Res.(Mohm) | 1000 | ||
| Input Cap.(Pf) | 0.5~1.5 | ||
| Cable length | 120cm | 120cm | 120cm |