SDO2000 SERIES DIGITAL OSCILLOSCOPE
Features
. 70MHz/100MHz/150MHz/200MHz bandwidth
. Independent double time base
. AUTO’s strategy presetable
. Lissajous figure supported
. Automatic measurement of 34 waveform parameters
. Automatic cursor tracking measurement function
. 2 channels, low noise floor, wide vertical range: 1mV/div~20V/div
. Built in FFT and digital filter
. System software upgrade via USB drive
. 7 inches TFT LCD,high resolution display 800×480
. Delicate window extension function and precise analysis on waveform details and overview
. Supports plug-and-play USB storage device; communication with and remote control of computer through the USB device
Technical Data | SDO2072 | SDO2102X | SDO2152 | SDO2202X |
Real-time Sample Rate | 500MS/s | 1GS/s | 500MS/s | 1GS/s |
Equivalent Sampling Rate | 50GS/s | 50GS/s | 50GS/s | 50GS/s |
Average Sampling Times | 2, 4, 8, 16, 32, 64, 128 and 256 | |||
Input Channel Specifications | ||||
Input coupling | DC, AC, GND | |||
Input Impedance | (1MΩ±2%)//(18pF±3pF) | |||
Probe attenuation coefficient | 0.01×/0.02×/0.05×/0.1×/0.2×/0.5×/1×/2×/5×/10×/20×/50×/100×/200×/500×/1000× | |||
Maximum input voltage | 300 Vrms,the transient over voltage is 1000 Vpk. | |||
Horizontal System Specification | ||||
Time-base scale | 2ns/div-50s/div | |||
Waveform interpolation | Sin(x)/x | |||
Time-base accuracy | ≤±(50 + 2×service life)ppm | |||
Record length | 2×512k sampling point | |||
Storage depth | Single channel: 64kpts;Double channel: 32kpts | |||
Sampling rate and delay time accuracy | ±50ppm (any time interval≥1ms ) | |||
Measurement accuracy of time interval (△T) | Single : ±(1 sampling time interval + 50ppm x reading + 0.6ns) >16 average values: ±(sampling time interval+50ppm×reading+0.4ns) | |||
Waveform capture rate | 5,000 wfms/s | |||
Vertical System Specification | ||||
Analog Bandwidth | 70MHz | 100MHz | 150MHz | 200MHz |
Rise Time(Typical) | ≤7ns | ≤3.5ns | ≤2.4ns | ≤1.8ns |
Channels | 2 | 2 | 2 | 2 |
Analog-to-digital converter (A/D) | 8 bits | 8 bits | 8 bits | 8 bits |
Deflection factor range | 1mV/div~20V/div(1MΩ) | |||
Position range | ≥±8div | |||
Selectable bandwidth limitation (Typical) | 20MHz | |||
Low frequency response (AC Coupling, -3dB) | ≤5Hz(above BNC) | |||
DC gain accuracy | 5mV~20V/div:≤±3%, 1mV~2mV/div:≤±4% | |||
DC measurement accuracy | When vertical position is 0 and N≥16: ± (4%×reading+0.1div+1mV) and selects 1mV~2mV/div; ± (3%×reading+0.1div+1mV) and selects 10mV~20V/div When vertical position is not 0 and N≥16: ±(3%×(reading + vertical position reading) + (1%×vertical position reading)+0.2div); The setting from 5mV/div to 200mV/div plus 2mV, the setting value from 200mV/div to 20V/div plus 50mV | |||
Measurement accuracy of voltage difference (△V) (average sampling mode) | Under the same setting and environment conditions and after averaging the captured waveforms with a quantity of ≥16, the voltage difference (ΔV) between any two points on the waveform: ±(3%×reading+0.05div) | |||
Trigger System Specification | ||||
Trigger sensitivity | ≤1div | |||
Range of trigger level | Int:From the screen center ±10div;Ext:±3V | |||
Trigger level accuracy (typical) (Signal with rising and falling time≥20ns) | Int:±(0.3div×V/div) (within±4 div from the screen center) Ext:±(6% setting value+40mV) | |||
Pre-trigger capacity | Normal mode/scan mode, pre-trigger/delay trigger the pre-trigger depth is adjustable | |||
Hold-off range | 80ns~1.5s | |||
Set the level to 50% (Typical) | Operate under the condition of input signal frequency of ≥50Hz | |||
Trigger mode | Auto, Normal, Single | |||
High-frequency hold off | Hold off signals over 80kHz | |||
Low-frequency hold off | Hold off signals below 80kHz | |||
Measurements | ||||
Cursor | Manual mode | Voltage difference between cursors (△V), Time difference between cursors (△T), Reciprocal of △T (Hz) (1/△T) | ||
Track mode | Voltage value and time value of point of waveform | |||
Auto mode | Cursor display is allowed on auto measurement mode | |||
Automatic measurement | Vpp,Vamp,Vmax,Vmin,Vtop,Vbase,Vmid,Average,Vrms,Overshoot,Preshoot, Frequency,Period,RiseTime,FallTime,+Width, -Width,+Duty,-Duty,Delay, FRFR,FFFR, FFFF, FRLF, FRLR,FFLR,FFLF | |||
Measurement quantity | Display 5 types of measurement at the same time | |||
Measurement scope | Screen or cursor | |||
Measurement statistics | Average value, maximum value, minimum value and standard deviation | |||
Math | ||||
Math operation | +, -, ×, ÷ | |||
Vertical scale | Rectangle, Hanning, Blackman, Hamming | |||
Digital filtering | Vrms, dBVrms | |||
Low pass, High pass, Band pass, Band reject | Low pass, High pass, Band pass, Band reject | |||
Trigger frequency meter | ||||
Reading resolution | 6bits | |||
Trigger sensitivity | ≤30Vrms | |||
Accuracy (Typical) | ±51ppm (+1 character) | |||
Storage | Internal: 20 groups. USB: 200 groups | |||
Display | 7-inch 800X480 color LCD | |||
Interface | Standard: USB Host, USB Device, EXT Trig,Pass / Fail. Option: LAN | |||
Power | 100V~240VACrms,50/60Hz,CAT II | |||
Size | 306mm(W)×138mm(H)×124mm(D) | |||
Weight | 2.5kg |